Mechanical and Aerospace Engineering

Organic Rankine Cycle (ORC) Binary Geothermal Plants Practice Exam, Flashcards & Questions

Master foundational to advanced Organic Rankine Cycle (ORC) Binary Geothermal Plants with 22 verified curriculum items, worked engineering solutions, and spaced-repetition cards.

16 Total Questions 4 MCQs 6 Calculations 2 Formulas 4 Flashcards
Free Interactive Preview

Organic Rankine Cycle (ORC) Binary Geothermal Plants Sample Exam Questions & Rationale

Preview official questions below. The complete pool of 16 items is available in the offline app.

Question 1 of 4 Pinch-Point Heat Exchanger Sizing

Where does the thermodynamic pinch point typically occur in a subcritical geothermal Organic Rankine Cycle brine vaporizer?

A At the onset of organic working fluid boiling (bubble point) inside the vaporizer heat exchanger
B At the exit of the cooling tower water return pump
C At the brine reinjection wellhead where pressure is highest
D At the superheater vapor outlet entering the turbine nozzle
Accepted Answer: Option A (At the onset of organic working fluid boiling (bubble point) inside the vaporizer heat exchanger)

Rationale: In a subcritical binary ORC evaporator, the pressurized organic fluid warms sensibly in the preheater and boils at constant temperature in the evaporator. Meanwhile, single-phase geothermal brine cools with a continuous linear temperature gradient. The minimum temperature difference between brine and working fluid (the pinch point) occurs at the onset of boiling (evaporator bubble point).

Question 2 of 4 Working Fluid Selection (Isopentane, R245fa)

Why are retrograde (dry) organic working fluids such as isopentane and R245fa preferred over wet fluids like water in binary geothermal Organic Rankine Cycles?

A Their positive saturated vapor slope ($dT/ds > 0$) prevents moisture condensation droplets during turbine expansion without requiring high superheating
B They eliminate the requirement for air-cooled condensers by dissipating heat entirely via nuclear radiation
C Retrograde organic fluids react endothermically with geothermal brine to double the net turbine inlet pressure
D They exhibit zero liquid viscosity at temperatures above ambient boiling point
Accepted Answer: Option A (Their positive saturated vapor slope ($dT/ds > 0$) prevents moisture condensation droplets during turbine expansion without requiring high superheating)

Rationale: Retrograde ('dry') working fluids have a positive slope on temperature-entropy diagrams ($dT/ds > 0$). When saturated vapor expands isentropically through an ORC turbine, it stays in the superheated vapor regime rather than crossing into the two-phase wet region. This eliminates liquid droplet erosion on turbine blading without necessitating large, costly superheaters.

Question 3 of 4 Pinch-Point Heat Exchanger Sizing

A geothermal brine shell-and-tube vaporizer transfers heat duty $\dot{Q} = 16.0\text{ MW}$ ($16{,}000\text{ kW}$) to an organic working fluid. The overall heat transfer coefficient is $U = 800\text{ W/(m}^2\cdot\text{K)}$ ($0.800\text{ kW/(m}^2\cdot^\circ\text{C)}$) and the calculated log-mean temperature difference is $\Delta T_{lm} = 12.5^\circ\text{C}$. Calculate the required heat transfer surface area $A$ in square meters ($\text{m}^2$).

A 1250 m^2
B 1600 m^2
C 2100 m^2
D 1450 m^2
Accepted Answer: Option B (1600 m^2)

Rationale: **Given:** Thermal heat duty $\dot{Q} = 16{,}000\text{ kW}$, overall heat transfer coefficient $U = 0.800\text{ kW/(m}^2\cdot^\circ\text{C)}$, log-mean temperature difference $\Delta T_{lm} = 12.5^\circ\text{C}$. **Formula:** $A = \frac{\dot{Q}}{U \cdot \Delta T_{lm}}$ **Calculation:** $A = \frac{16{,}000\text{ kW}}{0.800\text{ kW/(m}^2\cdot^\circ\text{C)} \times 12.5^\circ\text{C}} = \frac{16{,}000}{10.0} = 1600.0\text{ m}^2$ **Answer:** The required heat transfer area is 1600 m^2.

Question 4 of 4 Working Fluid Selection (Isopentane, R245fa)

An Organic Rankine Cycle turbine utilizes isopentane as working fluid with a mass flow rate $\dot{m}_{wf} = 120.0\text{ kg/s}$. Saturated vapor enters the turbine at enthalpy $h_1 = 615.0\text{ kJ/kg}$ and expands to condenser pressure at exhaust enthalpy $h_2 = 535.0\text{ kJ/kg}$. If the electrical generator mechanical-to-electrical efficiency is $\eta_g = 0.95$, calculate the generator electrical power output $P_e$ in megawatts ($\text{MW}$).

A 7.85 MW
B 9.12 MW
C 11.20 MW
D 6.45 MW
Accepted Answer: Option B (9.12 MW)

Rationale: **Given:** Working fluid mass flow $\dot{m}_{wf} = 120.0\text{ kg/s}$, turbine inlet enthalpy $h_1 = 615.0\text{ kJ/kg}$, turbine exhaust enthalpy $h_2 = 535.0\text{ kJ/kg}$, generator efficiency $\eta_g = 0.95$. **Formula:** $W_{turb} = \dot{m}_{wf} \cdot (h_1 - h_2)$ $P_e = W_{turb} \cdot \eta_g$ **Calculation:** $W_{turb} = 120.0\text{ kg/s} \times (615.0 - 535.0)\text{ kJ/kg} = 120.0 \times 80.0\text{ kW} = 9600.0\text{ kW}$ $P_e = 9600.0\text{ kW} \times 0.95 = 9120.0\text{ kW} = 9.12\text{ MW}$ **Answer:** The generator electrical power output is 9.12 MW.

Active Recall Spaced Repetition Cards (Preview)

Card 1 • Pinch-Point Heat Exchanger Sizing
The ORC {{c1::pinch point}} is the minimum temperature difference between brine and working fluid.
The pinch point temperature difference limits the minimum approach temperature between geothermal brine and organic working fluid.
Card 2 • Working Fluid Selection (Isopentane, R245fa)
Organic Rankine Cycle dry fluids prevent turbine {{c1::condensation droplet erosion}} during expansion.
Retrograde working fluids keep the expanding vapor dry, preventing liquid impingement erosion on ORC turbine blades.

Organic Rankine Cycle (ORC) Binary Geothermal Plants Curriculum Modules & Topics Covered

Modules
Binary Cycle Thermodynamics and Heat Exchangers
Core Exam Topics
  • Working Fluid Selection (Isopentane, R245fa)
  • Pinch-Point Heat Exchanger Sizing
Learning Objectives
  • Develop core conceptual recall and analytical problem-solving in Binary Cycle Thermodynamics and Heat Exchangers.

Free Downloadable Organic Rankine Cycle (ORC) Binary Geothermal Plants Study Packs (.ZIP / .TSV)

Full Spreadsheet Data (TSV)
TSV • 16 items
Complete Course Pack
ZIP • 16 items
Elements (Standard)
ZIP • 16 items
Active Recall Flashcards
ZIP • 16 items
Formula Codex
ZIP • 16 items
Problem Solving (Complete)
ZIP • 16 items
Problem Solving (Mastery)
ZIP • 16 items
Problem Solving (Standard)
ZIP • 16 items
Acoustic Cavitation & Sonoluminescence: Bubble Dynamics, Rayleigh-Plesset Equation & Shock Waves (48) Acoustic Wave Propagation: Wave Equation, Sound Pressure Level (SPL in dB) & Specific Acoustic Impedance (48) Acoustics & Vibration (1,211) Additive Manufacturing (45) Aeroacoustics: Lighthill's Acoustic Analogy, Jet Mixing Noise, Vortex Shedding Tone & Fan Noise Generation (48) Aerospace Engineering (4,254)
Full Question Pool: 16 Verified Items

Unlock All 16 Organic Rankine Cycle (ORC) Binary Geothermal Plants Practice Questions

Study the full question pool with 13 active recall battle modes, FSRS v5 spaced repetition, and 1-click printable PDF mock exams with full answer keys on Android and Windows PC.

Get on Google Play (Android) Get on Microsoft Store (Windows PC)